Boiler type Items | SZL6-1.25/1.6- AII | SZL6- 2.5- AII | SZL8-1.25/1.6- AII | SZL8- 2.5- AII | SZL10-1.25/1.6- AII | SZL10- 2.5- AII | SZL10-1.25/350- AII | SZL10-2.5/400- AII |
Rated output(t/h) | 6 | 6 | 8 | 8 | 10 | 10 | 10 | 10 |
Rated steam pressure (Mpa) | 1.25/1.6 | 2.5 | 1.25/1.6 | 2.5 | 1.25/1.6 | 2.5 | 1.25 | 2.5 |
Steam temperature °c | saturated | saturated | saturated | saturated | saturated | saturated | 350 | 400 |
Combustion mode | chain grate | |||||||
Applicable coal (bituminous coal) | AII AIII | |||||||
Open grate area(m²) | 7.2 | 7.2 | 9.9 | 9.9 | 11.99 | 13.1 | 13.1 | 13.1 |
Heated surface of boiler proper(m²) | 158.8 | 158.8 | 224.1 | 224.1 | 232.3/235 | 242.3 | 291.5 | 294.6 |
Heated surface of boiler tail(m²) | 87.2 | 105 | 105 | 125 | 221/244 | 244 | 229.6 | 265 |
The coal consumption at full load operation(Kg/h) | 968?971 | 972 | 1287?1289 | 1293 | 1380/1386 | 1394 | 1618 | 1673 |
Exhaust gas temperature°c | 170 | 170 | 170 | 170 | 170 | 170 | 170 | 170 |
Dust emission concentration(mg/Nm3) | <80 | <80 | <80 | <80 | <80 | <80 | <80 | <80 |
Identification of thermal efficiency % | 82.3 | 82.3 | 82 | 82 | 82.1 | 82.1 | 82.1 | 82.1 |
Maximum size of transportation cargo (L×W×H)mm | 5370×2970×3550 | 5740× 2830×3550 | 6720×3370×3550 | 6720×3370×3550 | 7530× 3340×3550 | 8830× 3340×3550 | 8830× 3370×3550 | 8800× 3400×3550 |
Maximum weight of transportation cargo (t) | 21.5/22.2 | 24.2 | 26.4?28 | 28.6 | 31?36 | 38 | 37.6 | 37.6 |
Installed exterior size (L×W×H)mm | 8200×2970×5600 | 8200×2830×5600 | 8200×3370×5600 | 8200×3370×5600 | 12100×3800×6030 | 13500×3800×6030 | 13500×3800×6500 | 12100×4500×6190 |
Notes:If main product capability parameter noted is changed,you shall refer to the technical documents on delivery. |