Mobile Control Coal Fired Hot Water Boiler Home Use Home Heater

Product Details
Customization: Available
Function: Hot Water Boiler
Fuel: Coal-Fired
Gold Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Years of Export Experience
The export experience of the supplier is more than 10 years
Overseas Services
The supplier provides overseas services and supports countries including Sri Lanka.

Overseas service content includes Training, Debugging.
Full Customization
The supplier provides full customization services
Flexible Customization
The supplier provides Flexible customization services for your Personalized requirements
to see all verified strength labels (13)
  • Mobile Control Coal Fired Hot Water Boiler Home Use Home Heater
  • Mobile Control Coal Fired Hot Water Boiler Home Use Home Heater
  • Mobile Control Coal Fired Hot Water Boiler Home Use Home Heater
  • Mobile Control Coal Fired Hot Water Boiler Home Use Home Heater
  • Mobile Control Coal Fired Hot Water Boiler Home Use Home Heater
  • Mobile Control Coal Fired Hot Water Boiler Home Use Home Heater
Find Similar Products

Basic Info.

Model NO.
CLSG
Installation
Packaged Boiler
Structure
Water Tube
Media
Hot Water
Water Circulation
Natural Circulation
Drum Placement
Horizontal Boiler
Pressure
Pressure
Manufacturing Level
A
Burning Style
Chamber Combustion Boiler
Usage
Home
Rated Thermal Power(MW)
0.046-2.8
Transport Package
Exported Standard/According to Requirement; FCL
Specification
SGS
Origin
China
HS Code
84031900
Production Capacity
10000 Units/Year

Product Description


Mobile Control Coal Fired Hot Water Boiler Home Use Home Heater
Mobile Control Coal Fired Hot Water Boiler Home Use Home Heater
Mobile Control Coal Fired Hot Water Boiler Home Use Home Heater
Characteristics

High efficiency than traditional product
Power-saving gasification and Oxygen - enriched combustion

 
Items                                               Boiler Type
GLAG0.035 CLSG0.046 CLSG0.07 CLSG0.092 CLSG0.12 CLSG0.14 CLSG0.19 CLSG0.23 CLSG0.3
Rated thermal power(MW) MW 0.035 0.046 0.07 0.092 0.12 0.14 0.19 0.23 0.3
Heat Value 10000Kcar 3 4 6 8 10 12 16 20 26
T 0.05 0.07 0.1 0.13 0.17 0.2 0.27 0.38 0.43
Heating Area m2 300 400 600 800 1000 1200 1600 2000 2600
Rated Working Pressure          MW 0 0 0 0 0 0 0 0 0
Rated effluent temperature ºC 85 85 85 85 85 85 85 85 85
Rated return water temperature ºC 60 60 60 60 60 60 60 60 60
Ringelmann Number Ringelmann black degree  <1 <1 <1 <1 <1 <1 <1 <185 <1
Designed heat efficiency   80 80 80 80 80 80 80 80 80
Outlet diameter DN 40 40 40 50 50 50 50 50 65
Drainage diameter DN 40 40 40 50 50 50 50 50 65
Discharge diameter DN 40 40 40 50 50 50 50 50 65
Water Capacity m3 0.15 0.18 0.4 0.6 0.7 0.8 0.9 0.98 1.2
Applicable coal   A III A III A III A III A III A III A III A III A III
Coal Consumption Kg/h 5 6.5 10 13 17 20 26 35 45
Bath Water Consumption(50ºC) t/h 0.5 0.75 1 1.5 2 2.5 3 4 5
Number of people   8 12 16 25 32 40 50 65 80
Chimney Size mm Φ140 x 3000 Φ140 x 3000 Φ140 x 4000 Φ140 x 4000 Φ140 x 5000 Φ140 x 5000 Φ140 x 6000 Φ140 x 6000 Φ140 x 6000
Installed size(LxWxH) mm 1010x1215x1700 1208x1300x2082 1258X1435X2214 2055x1615x2334 2135x1665x2510 2165x1722x2575 2280x1940x2632 2291x2155x2632 2523x1410x2683
Dimension(LxWxH) mm 1010x810x1461 1207x825x1460 1258X911X1560 1434x993x1726 1521x1045x1826 1536x1099x1866 1574x1172x1951 1580x1334x1951 1756x1282x2001
Total Weight T 0.35 0.4 0.55 0.65 0.75 0.82 0.91 1.1 1.3
 
Items                                                        Boiler Type    
CLSG0.35 CLSG0.046 CLSG0.58 CLSG0.7 CLSG0.92 CLSG1.05 CLSG1.4 CLSG1.75 CLSG2.1 CLSG2.45 CLSG2.8
Rated thermal power(MW) MW 0.35 0.046 0.58 0.7 0.92 1.05 1.4 1.75 2.1 2.45 2.8
Heat Value 104Kcar 30 40 50 60 80 90 120 150 180 210 240
  T 0.5 0.67 0.83 1 1.33 1.5 2 2.5 3 3.5 4
Heating Area m2 3000 4000 5000 6000 8000 9000 12000 15000 18000 21000 24000
Rated Working Pressure MW 0 0 0 0 0 0 0 0 0 0 0
Rated effluent temperature ºC 85 85 85 85 85 85 85 85 85 85 85
Rated return water temperature ºC 60 60 60 60 60 60 60 60 60 60 60
Ringelmann Number Ringelmann black degree  <1 <1 <1 <1 <1 <1 <1 <1 <1 <1 <1
Designed heat efficiency   80 80 80 80 80 80 80 80 80 80 80
Outlet diameter DN 65 80 80 80 100 100 125 125 150 150 150
Drainage diameter DN 65 80 80 80 100 100 125 125 150 150 150
Discharge diameter DN 65 80 80 80 100 100 125 125 150 150 150
Water capacity in furnace m3 1.43 1.83 2.1 2.4 2.8 3.693 4.57 5.6 6.65 7.4 8.5
Applicable coal   A III A III A III A III A III A III A III A III A III A III A III
Coal Consumption Kg/h 53 70 89 110 140 160 210 260 320 375 430
Bath Water Consumption(50ºC) t/h 6 7.5 10 15 20 22 30 37 45 52 60
Number of people   100 120 160 250 300 360 500 600 750 860 1000
Chimney Size  mm Φ165 x 6000 Φ219 x 6000 Φ219 x 6000 Φ219 x 6000 Φ273 x 6000 Φ273 x 6000 Φ325 x 6000 Φ325 x 6000 Φ325 x 6000 Φ325 x 6000 Φ377 x 6000
Installed size(LxWxH)  mm 2879x1470x2942 3037x1570x3085 3268x2601x3168 2055x1615x2334 4430x2970x3440 4818x2975x3251 5300x3204x3299 6000x3755x3300 6038x3796x3340 5308x3634x3300 6949x3755x3340
Overall dimension(LxWxH) mm 2074x1323x2100 2193x1444x2250 2258x1483x2234 1434x993x1726 3320x1800x2395 3710x1805x2351 4138x1809x2383 4575x2056x2384 4606x2200x2385 5111x2056x2385 5509x2039x2385
Weight T 1.8 2.3 2.6 3.2 4.3 5.5 7.2 7.6 8.8 9.5 11.8

Mobile Control Coal Fired Hot Water Boiler Home Use Home HeaterMobile Control Coal Fired Hot Water Boiler Home Use Home HeaterMobile Control Coal Fired Hot Water Boiler Home Use Home HeaterMobile Control Coal Fired Hot Water Boiler Home Use Home HeaterMobile Control Coal Fired Hot Water Boiler Home Use Home HeaterMobile Control Coal Fired Hot Water Boiler Home Use Home Heater