Automatic Controlled Coal Water Mixture Steam and Hot Water Series Boiler (Mixed Fuel Boiler) Power Plant EPC

Product Details
Customization: Available
Function: Steam Boilers, Hot Water Boiler
Fuel: Coal Water Mixture
Gold Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Years of Export Experience
The export experience of the supplier is more than 10 years
Overseas Services
The supplier provides overseas services and supports countries including Sri Lanka.

Overseas service content includes Training, Debugging.
Full Customization
The supplier provides full customization services
Flexible Customization
The supplier provides Flexible customization services for your Personalized requirements
to see all verified strength labels (13)
  • Automatic Controlled Coal Water Mixture Steam and Hot Water Series Boiler (Mixed Fuel Boiler) Power Plant EPC
  • Automatic Controlled Coal Water Mixture Steam and Hot Water Series Boiler (Mixed Fuel Boiler) Power Plant EPC
  • Automatic Controlled Coal Water Mixture Steam and Hot Water Series Boiler (Mixed Fuel Boiler) Power Plant EPC
  • Automatic Controlled Coal Water Mixture Steam and Hot Water Series Boiler (Mixed Fuel Boiler) Power Plant EPC
  • Automatic Controlled Coal Water Mixture Steam and Hot Water Series Boiler (Mixed Fuel Boiler) Power Plant EPC
  • Automatic Controlled Coal Water Mixture Steam and Hot Water Series Boiler (Mixed Fuel Boiler) Power Plant EPC
Find Similar Products

Basic Info.

Model NO.
SZS, YSL, YSW, SHF, SHFS
Structure
Fire Tube
Media
Steam or Hot Water
Water Circulation
Natural Circulation
Drum Placement
Vertical Boiler
Pressure
Low and Medium Temperature and Pressure
Manufacturing Level
A
Burning Style
Chamber Combustion Boiler
Usage
Industrial
Optional Pressure
0.7/1.0/1.25/1.6/3.82
Gas Flow Type
Fire Tube and Water Tube
Certification
SGS, Ce,ASME
Control System
PLC Optional
Transport Package
Exported Standard/According to Requirement; FCL
Specification
SGS, CE, ASME
Origin
China
HS Code
84021900
Production Capacity
500PCS/Year

Product Description

1. The clean fuel, manufactured by premium fuel, shall solve the pollution problem at the source.

2. The problems of high running cost for oil fired boiler shall be settled.

3. The product features environmental protection and energy-saving. Sulfer and dust contained in the flue gas and other environmental protection indexes shall surpass national standard.

4. Burn-out rate shall be more than 98 percent, and thermal efficiency shall be up to 85 percent or more.

5. Coal water mixture shall be transported and stored in liquid state. It shall be ignited automatically, with being automatic controlled easily, so it is the perfect substitude for oil fired boiler on environmental protection and energy-saving.

 
         Boiler type    Items SZS2-1.25-J SZS4-1.25-J SZS6-1.25-J SZS10-1.25-J
Rated output(t/h) 2 4 6 10
Rated working pressure (Mpa) 1.25 1.25 1.25 1.25
steam  temperature °c saturated saturated saturated saturated
Feedwater temperature °c 20 105 105 105
combustion mode  Chamber combustion Chamber combustion Chamber combustion Chamber combustion
Applicable fuel Coal water mixture Coal water mixture Coal water mixture Coal water mixture
Maximum weight of transportation cargo (t) 31.5 35.5 45 BULK
Maximum size of transportation cargo (L×W×H)mm 6300×3100×3540 7100×3400×3540 8700×3800×3600 14850×7800×10450
If main product capability parameter noted is changed,you shall refer to the technical documents on delivery.
   
  
                        Boiler type    Items YSL-700J YSL-1050J YSW-2800J
Thermal output(MW) 0.7(60) 1.05(90) 2.8(240)
Rated working pressure (Mpa) 0.7 0.7 1
The fuel consumption at full load operation(kg/h) 180 270 720
Rated working      temperature (°c) ≤300 ≤300 ≤300
The circulation oil        volume(m3) 51 76 163
Overall dimension (lengthxwidthxheight)mm 2740×2350×3290 3250×2360×3590 6900×2720×3460
Total weight of      equipments(t) 17.5 21.5 36
If main product capability parameter noted is changed,you shall refer to the technical documents on delivery.
 
                Boiler type    Items YSW-4200-J YSW-7000-J YSW-14000-J
Thermal output(MW) 4.2(360) 7.0(600) 14.0(1200)
Rated working          pressure (Mpa) 1 1 1
The fuel consumption at full load operation(kg/h) 1080 1800 3600
Heating area(m2) 271 350.3 735
Rated working temperature  (°c) ≤300 ≤325 ≤325
The circulation oil       volume(m3) 244 360 650
Overall dimension (lengthxwidthxheight)mm 8350×2900×3460 9700×3300×6460 17300×8550×11000
Total weight of equipments  (t) 48 87.5 177.5
 
           Boiler type      Items SHFS4-1.25-J SHFS6-1.25-J SHFS10-1.25-J SHFS20-1.6-SM SHFS35-3.82/450-SM SHFS75-3.82/450-SM
Rated output(t/h) 4 6 10 20 35 75
Rated working pressure (Mpa) 1.25 1.25 1.25 1.6 3.82 3.82
Steam temperature   °c saturated saturated saturated saturated saturated saturated
Rated feedwater temperature °c 20 105 105 105 105 105
Combustion  mode  Fluidization suspension combustion Fluidization suspension combustion Fluidization suspension combustion Fluidization suspension combustion Fluidization suspension combustion Fluidization suspension combustion
Applicable fuel Coal water mixture(CWM) Coal water mixture(CWM) Coal water mixture(CWM) Coal water mixture(CWM) Coal water mixture(CWM) Coal water mixture(CWM)
Maximum elevation of boiler proper(mm) 6000 6300 6700 8000 11100 14000
Overall dimension of installation for boiler proper(LxWxH)mm 8300×6800×6000 8500×6800×6300 10670×7550×6700 12650×7950×8000 15280×7950×11100 18100×1050×14000
 
           Boiler type                      
Items
SHFS2.8-1.0/115/70-J SHFS4.2-1.0/115/70-J SHFS7.0-1.0/115/70-J SHFS14.0-1.0/115/70-J SHFS29.0-1.0/115/70-J
Rated thermal power(MW) 2.8 4.2 7 14 29
Rated working pressure (Mpa) 1 1 1 1 1
Rated effluent temperature °c 115 115 115 115 115
Rated return water pemperature °c 70 70 70 70 70
Combustion mode  Fluidization suspension combustion Fluidization suspension combustion Fluidization suspension combustion Fluidization suspension combustion Fluidization suspension combustion
Applicable fuel Coal water mixture(CWM) Coal water mixture(CWM) Coal water mixture(CWM) Coal water mixture(CWM) Coal water mixture(CWM)
Maximum weight of transportation cargo(t) 6000 6300 6800 8000 11100
Overall dimension of installation for boiler proper(LxWxH)mm 8300×6800×6000 8500×6800×6300 15280×6950×6800 126507850×8000 15300×8050×11100

   
Automatic Controlled Coal Water Mixture Steam and Hot Water Series Boiler (Mixed Fuel Boiler) Power Plant EPC
 
Automatic Controlled Coal Water Mixture Steam and Hot Water Series Boiler (Mixed Fuel Boiler) Power Plant EPCAutomatic Controlled Coal Water Mixture Steam and Hot Water Series Boiler (Mixed Fuel Boiler) Power Plant EPCAutomatic Controlled Coal Water Mixture Steam and Hot Water Series Boiler (Mixed Fuel Boiler) Power Plant EPCAutomatic Controlled Coal Water Mixture Steam and Hot Water Series Boiler (Mixed Fuel Boiler) Power Plant EPC

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier