1. Higher working temperature shall be obtained under lower operating pressure.
2. Steady heating and accurate temperature adjustment shall be performed.
3. Under each grade loading, the thermal efficiency shall remain in a high level.
4. The boiler shall save power, water, as well as investment.
Boiler type Items | YGL 0.012 | YGL 120MW | YGL 0.24 | YGL350MW | YGL 450MW | YGL0.70 | YGL 0.95 | YGL 1.2 |
Thermal power MW(104Kcal) | 0.012(1) | 0.12(10) | 0.24(20) | 0.35(30) | 0.45(40) | 0.70(60) | 0.95(80) | 1.2(100) |
Rated working pressure (Mpa) | 0.7 | 1 | 1 | 1 | 1 | 1 | 0.7 | 0.7 |
Heating surface area(m²) | 3.06 | 14 | 23 | 48.28 | 55 | 63 | 74.3 | 74.3/34 |
Rated working temperature°c | 280 | 300 | 300 | 300 | 300 | 300 | 300 | 300 |
Oil capacity in furnace(m3) | 0.011 | 0.12 | 0.25 | 0.38 | 0.6 | 0.8 | 0.86 | 0.9 |
The circulation oil volume(m3) | 2.12 | 8.22 | 16.7 | 23.8 | 40 | 51.9 | 55.3 | 69.89 |
Overall dimensions (LxWxH)mm | ø1000×1400 | ø1640×2540 | ø1770×2760 | ø1950×3360 | ø2090×3790 | ø2090×4440 | ø2340×5050 | ø2340×5080 |
Total power(kw) | 1.5 | 5.1 | 6.6 | 10.25 | 15 | 23.6 | 26.25 | 41.25 |
Connected diameter of piping Dn(mm) | 25 | 40 | 50 | 80 | 80 | 100 | 125 | 125 |
Total weight of equipments(Kg) | 1300 | 2882 | 3630 | 4860 | 6305 | 6607 | 9165 | 9235 |
Boiler type Items | YGL 1.4 | YGL 1.8 | YLL 0.95 | YLL 1.2 | YLL 1.4 | YLL 1.8 | YLW 1.8 | YLW 2.4 | YLW 3.5 | YLW 4.2 |
Thermal power MW(104Kcal) | 1.4(120) | 1.8(160) | 0.95(80) | 1.2(100) | 1.4(120) | 1.8(160) | 1.8(160) | 2.3(200) | 3.5(300) | 4.2(360) |
Rated working pressure (Mpa) | 1 | 1 | 0.7 | 0.7 | 1 | 0.7 | 0.7 | 0.7 | 1 | 1 |
Heating surface area(m²) | 86.4 | 97 | 74.3 | 74.3/34 | 86.2/27.5 | 107.3/32 | 83.6/32 | 83.6/32 | 180 | 255 |
Rated working temperature°c | 300 | 300 | 300 | 300 | 300 | 300 | 300 | 300 | 320 | 320 |
Oil capacity in furnace(m3) | 0.95 | 1.26 | 0.86 | 0.9 | 0.95 | 1.26 | 1.4 | 1.6 | 2.71 | 2.92 |
The circulation oil volume(m3) | 81.5 | 106 | 55.33 | 69.9 | 81.5 | 84.1 | 104.8 | 134 | 200 | 58 |
Overall dimensions (LxWxH)mm | ø2470×5340 | ø2450×6080 | 4750×2162×5370 | 4750×2162×5460 | 5050×2165×5330 | 5850×2162×4890 | 5850×2162×4680 | 5850×2162×4680 | 6900×2720×5280 | 6600×3200×5750 |
Total power(kw) | 43.95 | 46.5 | 25.5 | 40.5 | 41.75 | 45.75 | 56.75 | 61.75 | 92.5 | 119.5 |
Connected diameter of piping Dn(mm) | 125 | 125 | 125 | 125 | 125 | 125 | 150 | 150 | 150 | 200 |
Total weight of equipments(Kg) | 10120 | 11655 | 16432 | 16600 | 18990 | 22022 | 23559 | 29529 | 32680 | 41680 |
Boiler type Items | YLW 5.0 | YLW 6 | YLW 7.0 | YLW 9.5 | YLW 12 | YLW 14 | LYG Δ 0.15 | SZG Δ 0.35 |
Thermal power MW(104Kcal) | 5.0(420) | 6.0(500) | 7.0(600) | 9.5(800) | 12(1000) | 14(1200) | 0.15(12) | 0.35(30) |
Rated working pressure (Mpa) | 1 | 1 | 0.7 | 1 | 1 | 1 | 0.3 | 0.4 |
Heating surface area(m²) | 291 | 413.5 | 479 | 582.4 | 735.4 | 799.4 | 6.86 | 21.8 |
Rated working temperature°c | 300 | 300 | 300 | 300 | 300 | 300 | 320 | 320 |
Oil capacity in furnace(m3) | 3.01 | 3.5 | 4.1 | 5.4 | 6.8 | 8.3 | 0.6 | 0.8 |
The circulation oil volume(m3) | 300 | 350 | 400 | 400 | 400 | 400 | / | / |
Overall dimensions(LxWxH)mm | 7300×3200×5750 | 7840×3400×6340 | 8720×3400×5400 | 9340×3780×5870 | 10665×3560×6050 | 10865×4120×6600 | 1800×1678×2520 | 3500×1900×2600 |
Total power(kw) | 138 | 142.8 | 153.9 | 157.4 | 188.9 | 225.9 | / | 7.5 |
Connected diameter of piping Dn(mm) | 200 | 250 | 250 | 250 | 250 | 300 | 80 | 100 |
Total weight of equipments(Kg) | 43410 | 60023 | 63360 | 78720 | 81000 | 113063 | 3072 | 9250 |
The sign of Δ in the above table shall be referred to gas phase heat transfer oil stove. |